
Uni-strut and clamps used as fire sprinkler pipe hangers
Nov 30, 2006 · WE are seeing more and more cases of unistrut type systems fastening sprinkler piping to building structure. If oriented so that piping is not hanging down against the clamp, the shear or …
NFPA #13, Trapeze Hangers & Unistrut. | Eng-Tips
May 23, 2008 · I would also note that unistrut (generic) is NOT listed in any NFPA "tables". So while you see NFPA 13 showing examples of how to determine the section moduls for and angle iron trapeze …
Building a three tier brew stand with Unistrut - Homebrew Talk
Jul 3, 2007 · I could use Unistrut Product Group or Unistrut Product Group I planned on a three tier verticle tower..with square frames off of the main pole for three burners..it seems simple but wanted …
Strength of unistrut section | Eng-Tips
Sep 9, 2004 · I been trying to figure out the strength of a channel shape unistrut bar bolted on a rolling load table, which will be subjected to a concentrated load applied through a ball screw. Would some …
Unistrut Yield Strength | Eng-Tips
Nov 14, 2016 · Unistrut reported to me that their Unistrut steel is 33 ksi steel that has been cold rolled to 42 ksi. Does that happen because of compression during the cold rolling process? If not, how, then is …
Cantilever Calculation for a Unistrut Beam | Eng-Tips
Jan 21, 2018 · Hi all, this might be novice stuff, but I am a novice. The reading I have done explains how to work out the forces and moments on a static cantilever beam, but not what is required at the …
Unistrut Properties Calculation | Eng-Tips
Aug 11, 2009 · I have a project in Los Angeles in which I have specified a considerable amount of unistrut. I specified the unistrut based on the published allowable values in the Unistrut catalog. LA …
Unistrut Weld Detail | Eng-Tips
Feb 12, 2019 · What do you guys think about this detail? The legs of the unistrut are facing downwards. The load is only about 150bs. The existing unistruts are already welded in this manner so I am trying …
Unistrut in Torsion | Eng-Tips
Jun 10, 2025 · Unistrut is setup so that local buckling is probably a non-issue. I certainly don't go out of my way to use unistrut in torsion for primary loads but, for small stuff, I'm sure it works. .unistrut is …
Unistrut Connection Capacity for General Fittings | Eng-Tips
Mar 17, 2015 · I am putting together some drawings for a multi-discipline utility rack and I'm using Unistrut tracks and fittings. Their engineering catalog shows beam and column capacities for their …